1.76 LPG PUMP LITEARTURES

LPG PUMPS SPECIFICATIONS

AC LPG PUMP WITH SPARES

AC LPG PUMP

 

 

AC LPG PUMP TECHNICAL SPECIFICATIONS

Pump Type:- AC (Electric supply) LPG Diaphragm Pump,
Pump Make:- “MALHAR”
Pump Model:- MD-AC-1 ,
Suction x Delivery Sizes:- ¼ ” x ¼ ”,
Pump Capacity :- 15 kg/7 Minute I.E 2.14 kg/Minute,
Maximum Pressure :- 22 kg/cm2,
Pump Weight :-16 kg approx

Motor Specifications

0.5 hp x 1450 rpm , Non Flame Proof Motor Totally enclosed Fan cooled Squirrel cage Induction Motors Horizontal Foot mounted B3 Construction, Continuously rated S1 Duty suitable for single phase , 220 volts , 50 Hz , AC Supply (110 volts or 60 Hz Available on request) with ambient 45ºc & class “F” Insulation.

 

Material Of Construction

Standard Cast Iron Construction,

SCOPE OF SUPPLY

Ac lpg Pump With Suction and Delivery Pipes with Valve, Regulator and extra Diaphragm.

FLAME PROOF AC LPG PUMP

 

FLAME PROOF AC LPG PUMP
Useful for industrial applications

FLAME PROOF AC LPG PUMP TECHNICAL SPECIFICATIONS

Pump Type:- AC (Electric supply) LPG Diaphragm Pump With flp motor,
Pump Make:- “MALHAR”
Pump Capacity :- 15 kg/7 Minute I.E 2.14 kg/Minute,
Pump Model:- MD-AC-FLP-1 ,
Suction x Delivery Sizes:- ¼ ” x ¼ ”,
Maximum Pressure :- 22 kg/cm2
Pump Weight :- 24 kg approx,

Motor Specifications

0.5 HP X 1450 RPM,“MALHAR” , OR Equivelent Make NON CMRI Flame Proof Electric Motor Foot Mounted (B3 Construction) Totally Enclosed Fan Cooled Suitable for 415 volt ,50 Hz , 3 phase Supply with class “1” Division – 2 , Group-D Insulation Degree of Protection IP-55 as per IS:4691 with bare shaft & key , Continuous rated S1 Duty & suitable for Gas groups I , IIA , IIB as per IS: 2148-1981 copper winding.
If Required we will give you CMRI CERTFIED “PEW” OR “CROMPTON” Make also.

 

Material Of Construction

Standard Cast Iron Construction,

SCOPE OF SUPPLY

FLP AC lpg Pump With Suction and Delivery Pipes with Valve, Regulator and extra Diaphragm.

DC LPG PUMP

 

AC LPG PUMP

 

 

DC LPG PUMP TECHNICAL SPECIFICATIONS

Pump Type:- 12 Volt DC (Battery Operated ) LPG Diaphragm Pump,
Pump Make:- “MALHAR”
Pump Model:- MD-DC-1,
Suction x Delivery Sizes:- ¼ ” x ¼ ”,
Pump Capacity :- 15 kg/7 Minute I.E 2.14 kg/Minute,
Maximum Pressure :- 22 kg/cm2,
Pump Weight :- 16 kg approx

DC Motor Specifications

12 Volt DC PMDC Motor suitable for above pump, Take approximately 3 ampere current.

 

Material Of Construction

Standard Cast Iron Construction,

SCOPE OF SUPPLY

Dc lpg Pump With Suction and Delivery Pipes with Valve, Regulator and extra Diaphragm.

AC LPG PUMP AND DC LPG PUMP SPARES

MANUAL LPG PUMP

MANUAL HAND OPERATED PUMP

MANUAL FOOT OPERATED PUMP

 

MANUAL LPG PUMP TECHNICAL SPECIFICATIONS

Pump Type:- Manual LPG Pump Piston Type 4 way non Return Valve Arrangement,
Pump Make:- “MALHAR”,
Pump Capacity :- 15 kg/15 Minute i.e. 1 kg/Minute , depend on nos of stroke per minute,
Pump Model:- MMLPG-1,
Suction X Delivery sizes:- ¼ ” x ¼ ”,”
Maximum Pressure :- 20 kg/cm2
Pump Weight :- 6 kg approx

 

Material Of Construction

Standard Cast Iorn Construction,

SCOPE OF SUPPLY

Manual lpg Pump With Suction and Delivery Pipes with Valve , Regulator, extra piston ring and Handle will come separately

ROTARY VANE LPG PUMP

 

ROTARY VANE PUMP TECHNICAL SPECIFICATIONS

Pump Type:- Rotary Vane Pump,
Pump Make:- “MALHAR”
Pump Model:- RV-1,
Inlet x Outlet size :- ½” x ½”BSP,
Pump Capacity :- 7 kg/minute,
Maximum Pressure :- 15 kg/cm2,
Pump Weight :- 5 kg approx (with out motor)

Required Motor Specifications

1 hp x 2900 rpm , Non Flame Proof Motor Totally enclosed Fan cooled Squirrel cage Induction Motors Horizontal Foot mounted B3 Construction, Continuously rated S1 Duty suitable for single phase , 220 volts , 50 Hz , AC Supply (110 volts or 60 Hz Available on request) with ambient 45ºc & class “F” Insulation.

 

Material Of Construction

Standard Cast Iron Construction With Bronze Vane,

OR

IF YOU REQUIRED ROTARY VANE PUMP WITH FLP MOTOR

Required FLAME PROOF Motor Specifications

1 HP X 2900 RPM,“MALHAR” , OR Equivelent Make NON CMRI Flame Proof Electric Motor Foot Mounted (B3 Construction) Totally Enclosed Fan Cooled Suitable for 415 volt ,50 Hz , 3 phase Supply with class “1” Division – 2 , Group-D Insulation Degree of Protection IP-55 as per IS:4691 with bare shaft & key , Continuous rated S1 Duty & suitable for Gas groups I , IIA , IIB as per IS: 2148-1981 copper winding.

If Required we will give you CMRI CERTFIED “PEW” OR “CROMPTON” Make also

 

SCOPE OF SUPPLY

Rotary vane Pump only (with motor or with out motor)

WE ALSO GIVE EUROPIAN FITTINGS FOR LPG CAR

 

LPG PUMP INSTRUCTIONS

CAUTION : DO NOT SMOKE / USE MOBILE WHILE USING PUMP

1. Bring Pump Out Carefully From Box

2. Star The Pump without Connecting Pipes and check Inlet &Out let.

3. Vacuum on One side and pressure on other side .It is in & Out of Pump.

4. Place Pipe (1) at In & Out Pipe (2) At Out Side

5. Turn Bottle Download and Fix Pipe

6. Put Pipe (2) to Another Bottle / Car

7. Now Start Open Valve Of Pipe (1)

8. Also Open Valve Of Pipe-2

9. Start Pump.

10. You can see Liquid Transfer from Pump through Glass

11. In case If Pressure Exceed, Up To 10 Kg/cm2,Then Gas will By Pass and Transfer in to Inlet Pipe Again.

12. If Sometime Pressure Increase more than 20kg/cm2, Then Stop Pump Immediately, Also sometime pump may stop automatically but some time Diaphragm may Rapture.

13. Bottle Empty, Pump Noise will be Different and also you can see No Liquid Transfer in Glass

14. Now stop pump, Remove suction & Delivery pipe from bottle & car put Pump in Box

15. Video of Transfer of gas / changing Of Diaphragm enclosed.

PRECAUTION

:- Never Closed Delivery side Valve when pump is running , otherwise Diaphragm will be damaged.